Mid Construction
Pre Drywall Site Readiness

Before your blower door or airtightness test can be conducted at the pre-drywall stage, please ensure all of the following items have been completed. This helps ensure an accurate test result and avoids delays on site.

Pre-Test Checklist

  • Cover and seal missing or broken window or exterior door openings
  • Close and latch all windows.
  • Close all exterior doors (Ensure door hardware has been installed)
  • Close or seal the attic hatch.
  • Close or seal the crawl space access.
  • Close or seal all knee wall access doors.
  • Fill all floor drains with water.
  • Fill all plumbing traps with water.
  • Ensure there are reliable and accessible electrical hookups on site that can be used for testing

If you have any questions about site preparation or need to reschedule your test, please contact us at 1-877-541-4280.